No ACF gallery field data found

HUAWEI CXLQ41 SSRD0CXLQ41 4xSTM-4 CXLQ41(L-4.1,LC) Transmission for Huawei

Brand Name: Huawei
Model Number: CXLQ41
Minimum Order Quantity: 1 pc
Price: 
Delivery Time: 3-5 days
Warranty Time: 
Place of Origin: China
Payment Terms: 

Description

HUAWEI CXLQ41 SSRD0CXLQ41 4xSTM-4 CXLQ41(L-4.1,LC) Transmission for Huawei ​ Product Description: OptiX OSN3500 System Features Subrack dimensions 498mm(W) X 287mm (D)X 700mm (H) Switching capacity Packet: 100 Gbit/s. TDM: 200 Gbit/s (high order), 20 Gbit/s (low order) Service slots 15 slots for processing boards and 16 slots for interface boards Highly reliable design 1+1 hot backup for power supply modules 1+1 hot backup for system control boards 1+1 hot backup for cross-connect and synchronous timing boards Redundancy protection for fan modules Supported interfaces Packet transport interfaces E1, STM-1, FE/GE/10GE MSTP interfaces STM-64/16/4/1, E1/E3/E4/T1/T3, FE/GE/10GE, DDN, IMA/ATM, SAN WDM interfaces 40-channel DWDM interfaces, compliant with ITU-T G.694.1 8-channel CWDM interfaces, compliant with ITU-T G.694.2 Power Supply 48V DC, 110/220V AC (External module) Operation Environment Temperature Relative Humidity Long term: 0C to 45C 10% to 90% Short term: 5C to 55C 5% to 95% Packet Transport Features Service features E-Line and E-LAN QinQ MPLS-TP based VPWS and VPLS TDM PWE3: CESoPSN and SAToP, compression of idle timeslots ETH PWE3 IGMP SNOOPING V2 Blacklist Broadcast packet suppression ACL QoS features H-QoS scheduling and traffic shaping DiffServ mode based on traffic classification Simple traffic classification, complex traffic classification, per hop behavior (PHB), and ACL Committed access rate (CAR) PQ scheduling priority, weighted fair queuing (WFQ), and PQ+WFQ queuing Tail drop and weighted random early detection (WRED) Eight priority queues Shaping based on port scheduling priority Hardware-based OAM MPLS OAM Supports both LSP OAM and PW OAM: CV (Connectivity Verification) FFD (Fast Failure Detection) FDI (Forward Defect Indicator) BDI (Backward Defect Indicator) CES PW VCCV Ping Traceroute Ethernet OAM ETH-CC (continuity check), ETH-loopback, ETH-link trace Remote loopback, remote fault detection RMON (RFC 2819) LM, DM MAC/PHY loopback Carrier-class protection 1+1 and 1:1 Linear MSP, guaranteeing 50 ms switching time 1+1 and 1:1 protection for label switched path (LSP) and pseudo-wire (PW), guaranteeing 50 ms switching time Multi-section pseudo-wire (MS-PW) Link aggregation group (LAG) protection Multi-chassis link aggregation group (MC-LAG) protection Dual-homing protection LPT STP/RSTP/MSTP Clock synchronization Two external clock inputs/outputs (2 MHz or 2 Mbit/s) Two external time signals (1 pps+TOD) Adaptive clock recovery (ACR) Synchronous Ethernet IEEE 1588v2 MSTP Features Interface Electrical interfaces: DDN (V.35/V.24/X.21/RS-449/RS-530/RS-530A), E1/T1, E3/T3, E4, STM-1(E), 10/100BASE-TX, 1000BASE-T Optical interfaces: - Ethernet 100base-FX, 1000BASE-SX/LX/ZX, 10GBASE-LR/LW - STM-1 S-1.1, L-1.1, L-1.2 - STM-4 S-4.1, L-4.1, L-4.2 - STM-16 I-16, S-16.1, L-16.1, L-16.2, V-16.2, U-16.2 - STM-64 I-64.2, S-64.2, L-64.2b, P1L1-2D2, V-64.2 - 40-channel DWDM interfaces (FEC off band), compliant with ITU-T G.694.1 - 8-channel CWDM interfaces, compliant with ITU-T G.694.2 - Others: FC/ESCON/DVB-ASI Carrier-class protection Mesh Protection and restoration (ASON) -Distributed restorable rerouting protection -Five dedicated protection scheme levels based on different SLA: Diamond, Gold, Silver, Copper and Iron SDH Network Protection 2/4 fiber MS-SP Ring, 1+1 or 1:n (n<,=14) linear MSP, SNCP/SNCMP/SNCTP,, fiber shared virtual path protection, fiber shared MS-SP Ring (one optical interface can support 2 groups of MS-SP Rings), DNI (ITU-T G.842) Service Protection Ethernet: RPR, ERPS, RSTP, LAG/DLAG/PPS/BPS ATM: VP-RING, PPS/BPS Electrical Interface Protection 1:n tributary protection for E1/T1, E3/T3, E4, STM-1(e), and FE Multi-service Transport Features Ethernet Over SDH - GFP/LAPS/VCAT/LCAS - L2 switch, 64 aggregation directions for powerful Ethernet convergence - Mapping granularity, VC-12-nv/VC-3-nv, and VC-4-nv - Point-to-point LPT, point-to-multi-point LPT - MPLS and stackable VLAN for L2 VPN - 4/8-level CoS, CAR based on 64K granularity - IEEE 802.3ah, 802.1ag RPR - Automatic topology discovery - 3-level CoS, A (A0/A1) / B (B-CIR/B-EIR) / C - Steering/Wrapping/Steering + Wrapping protection scheme guarantee 50ms switching - Spatial reuse of bandwidth with fairness algorithm - Integrated MPLS with RPR to provide VLL/VPLS service ATM - Support 2M, 34M, 155M, 622M ATM, and IMA E1 - Support up to 93 IMA group and 189 E1s Others - Support FC/ESCON/DVB-ASI - Support DDN (Nx64K) and framed E1 Service interfaces of the OptiX OSN3500: Interface Type Description SDH service interface STM-1 electrical interfaces: SMB connectors and SAA connectors STM-1 optical interfaces: I-1, Ie-1, S-1.1, L-1.1, L-1.2, Ve-1.2 STM-4 optical interfaces: I-4, S-4.1, L-4.1, L-4.2, Ve-4.2 STM-16 optical interfaces: I-16, S-16.1, L-16.1, L-16.2, L-16.2Je, V-16.2Je, U-16.2Je STM-16 optical interfaces (FEC): Ue-16.2c, Ue-16.2d, Ue-16.2f STM-64 optical interfaces: I-64.1, I-64.2, S-64.2b, L-64.2b, Le-64.2, Ls-64.2, V-64.2b, P1L1-2D2 STM-64 optical interfaces (FEC): Ue-64.2c, Ue-64.2d, Ue-64.2e STM-16 and STM-64 optical interfaces that comply with ITU-T G.692 can output fixed wavelength from 191.1 THz to 196.0 THz, and can directly be interconnected with the WDM equipment. PDH service interface 75/120-ohm E1 electrical interfaces: DB44 connectors 100-ohm T1 electrical interfaces: DB44 connectors 75-ohm E3, T3 and E4 electrical interfaces: SMB connectors Ethernet service interface 10/100BASE-TX, 100BASE-ZX, 100BASE-VX, 100BASE-LX, 100BASE-FX, 1000BASE-VX, 1000BASE-SX, 1000BASE-LX, 1000BASE-ZX, 1000BASE-T, 10GBASE-LW, 10GBASE-LR DDN service interface RS449, EIA530, EIA530-A, V.35, V.24, X.21, and framed E1 interface ATM service interface STM-1 ATM optical interfaces: Ie-1, S-1.1, L-1.1, L-1.2, Ve-1.2 STM-4 ATM optical interfaces: S-4.1, L-4.1, L-4.2, Ve-4.2 E3 interfaces: E3 services are accessed by the E3 board IMA E1 interfaces: IMA E1 services are accessed by the E1 board Storage area network (SAN)/Video service interface FC100, FICON, FC200, ESCON, or DVB-ASI service optical interfaces SDH boards that the OptiX OSN3500 supports: Board Description Board Description N1SL64, N2SL64, N4SL64 1xSTM-64 optical interface board N1SLD4, N2SLD4 2xSTM-4 optical interface board N1SF64, N1SF64A, N4SF64 1xSTM-64 optical interface board (with the forward error correction (FEC) function) N1SLD4A 2xSTM-4 optical interface board N1SLD64and N4SLD64 2xSTM-64 optical interface board N1SLT1 12xSTM-1 optical interface board12xSTM-1 optical interface board N1SL16, N2SL16, N3SL16 1xSTM-16 optical interface board N1SLQ1, N2SLQ1 4xSTM-1 optical interface board N1SL16A, N2SL16A, N3SL16A 1xSTM-16 optical interface board N1SLQ1A 4xSTM-1 optical interface board N1SLD16 2xSTM-16 optical interface board N1SL1, N2SL1 1xSTM-1 optical interface board N1SLQ16, N2SLQ16, N4SLQ16 4xSTM-16 optical interface board N1SL1A 1xSTM-1 optical interface board N1SF16 1xSTM-16 optical interface board (with the out-band FEC function) N1SLH1 16xSTM-1 signal processing board N1SLO16 8xSTM-16 optical interface board N1SEP1 2xSTM-1 line processing board when the interfaces are available on the front panel 8xSTM-1 line processing board when the interfaces are available on the corresponding interface board N1SL4, N2SL4, N1SL4A 1xSTM-4 optical interface board N2SLO1, N3SLO1 8xSTM-1 optical interface board N1SLQ4, N2SLQ4, N1SLQ4A 4xSTM-4 optical interface board N3SLQ41 4xSTM-4/STM-1 optical interface board N1EU08 8xSTM-1 electrical interface board N1OU08 8xSTM-1 optical/ electrical interface board (LC) N2OU08 8xSTM-1 optical interface board (SC) N1EU04 4xSTM-1 electrical interface board PDH boards that the OptiX OSN3500 supports: Board Description Board Description N1PQ1, N2PQ1 63xE1 service processing board N2PQ3 12xE3/T3 service processing board N1PQM 63xE1/T1 service processing board N1DX1 DDN service accessing and converging board N1PL3, N2PL3 3xE3/T3 service processing board N1DXA DDN service converging and processing board N1PL3A, N2PL3A 3xE3/T3 service processing board (The interfaces are available on the front panel.) N1SPQ4, N2SPQ4 4xE4/STM-1 electrical processing board N1PD3, N2PD3 6xE3/T3 service processing board N1MU04 4xE4/STM-1 electrical interface board N1D75S 32xE1 switching access board (75 ohms) N1D34S 6xE3/T3 switching access board N1C34S 3xE3/T3 switching access board N1D12S 32xE1/T1 switching access board (120 ohms) N1D12B 32xE1/T1 access board (120 ohms) N1DM12 DDN service interface board N1TSB4 4-channel electrical interface protection switching board N1TSB8 8-channel electrical interface protection switching board ATM boards that the OptiX OSN3500 supports Board Description Board Description N1ADQ1 4xSTM-1 ATM service processing board N1ADL4 1xSTM-4 ATM service processing board N1IDQ1, N1IDQ1A 4xSTM-1 ATM service processing board N1IDL4, N1IDL4A 1xSTM-4 ATM service processing Product Detail: If you are interested, please let us know the specific model. We will provide the best service and the best price! Pr

Tags

magnifier