No ACF gallery field data found

Cisco Switch WS-C3850-24U-S Stackable 24 10/100/1000 UPOE Ports 1 Network Module Slot 1100W Power

Brand Name: Cisco
Model Number: WS-C3850-24U-S
Minimum Order Quantity: 1 pc
Price: 
Delivery Time: 3-5 days
Warranty Time: 
Place of Origin: China
Payment Terms: 

Description

Cisco Switch WS-C3850-24U-S Stackable 24 10/100/1000 UPOE ports, 1 network module slot, 1100 W power WS-C3850-24U-S Overview Cisco WS-C3850-24U-S supports Stackable 24 10/100/1000 Cisco UPOE ports, 1 network module slot, 1100 W power supply and 1RU chassis. Cisco Catalyst 3850 Series provides capabilities that ideally suited to support the convergence of wired and wireless access. The new Cisco Unified Access Data Plane (UADP) Application-Specific Integrated Circuit (ASIC) powers the switch and enables uniform wired-wireless policy enforcement, application visibility, flexibility, and application optimization. This convergence is built on the resilience of the new and improved Cisco StackWise-480 technology. WS-C3850-24U-S Specification WS-C3850-24U-S Specification model info: WS-C3850-24U-S enclosure type Rack-mountable - 1U Ports Stackable 24 10/100/1000 Cisco UPOE ports Network management Interface в—Џ Ethernet management port: RJ-45 connectors, 4-pair Cat-5 UTP cabling в—Џ Management console port: RJ-45-to-DB9 cable for PC connections Available PoE Power 800W Maximum stacking number up to 9 switches with same IOS feature set in same series Stack Bandwidth 480Gbps CPU Multicore CPU RAM 4 G Flash Memory 2 G Wireless Number of AP per switch/stack 100 Number of wireless clients per switch/stack 2000 Total number of WLANs per switch 64 Wireless bandwidth per switch up to 20Gbps Supported Aironet AP series 3600, 3500, 2600, 1600, 1260, 1140, 1040 Expansion / Connectivity Console ports USB (Type-B), Ethernet (RJ-45) Expansion Slot(s) 1 network module slot and 1 power redundant slot Network Modules Selection C3850-NM-4-1G C3850-NM-2-10G Stacking cable в—ЏSTACK-T1-50CM StackWise stacking cable with a 0.5 m length в—ЏSTACK-T1-1M StackWise stacking cable with a 1.0 m length в—ЏSTACK-T1-3M StackWise stacking cable with a 3.0 m length Stack Power Cable (recommended) в—ЏCAB-SPWR-30CM stack power cable with a 30CM length в—ЏCAB-SPWR-150CM stack power cable with a 150CM length Power supply PWR-C1-1100WAC/2= Power Device Power supply - redundant - plug-in module Power Redundancy optional Voltage range (Auto) 100V-240V Power Consumption of standalone(in Watts) 84.97 (max) Miscellaneous Dimensions (H x W x D) 1.75 x 17.5 x 19.2 inch, 4.45 x 44.5 x 48.8 cm Rack Mounting Kit optional MTBF in hours 237,310 Compliant Standards в—Џ IEEE 802.1D Spanning Tree Protoco в—Џ IEEE 802.1p CoS Prioritization в—Џ IEEE 802.1Q VLAN в—Џ IEEE 802.1s в—Џ IEEE 802.1w в—Џ IEEE 802.1X в—Џ IEEE 802.1X-Rev в—ЏIEEE 802.11 в—Џ IEEE 802.1ab (LLDP) в—Џ IEEE 802.3ad в—Џ IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports в—Џ IEEE 802.3 10BASE-T в—Џ IEEE 802.3u 100BASE-TX в—Џ IEEE 802.3ab 1000BASE-T в—Џ IEEE 802.3z 1000BASE-X в—Џ RMON I and II standards в—Џ SNMP v1, v2c, and v3 System software / license System software IOS IP Base EnergyWise license ENERGY-MGMT, ENERGY-MGT-100-K9 Features в—ЏRPS Support в—Џ Jumbo Frames в—Џ VLANS в—ЏVoice Vlan в—ЏVTPv2 в—ЏCDPv2 в—ЏLLDP в—Џ 802.3ad LACP and PAgP в—Џ PVST/PVST+ в—Џ 802.1W/802.1S в—ЏPort Fast/Uplink Fast в—ЏDynamic Trunking Protocol (DTP) в—Џ port CoS Trust and Override в—Џ Trusted Boundary в—Џ ACL Classification в—Џingress Policing в—Џ Auto QoS в—Џ Per VLAN policies в—Џ 802.1p queues в—Џ Scheduling в—Џ Priority Queuing в—Џ Configure CoS Priority Queues в—ЏConfigure CoS Priority Queues в—Џ Configure Queue Weights в—Џ Configure Buffers and Thresholds в—ЏClass Policy Maps в—Џ Modify CoS and DSCP Mapping в—Џ Weighted Tail Drop в—Џ IGMPv1,v2,v3 and MLDv1, v2 в—Џ DHCP server в—Џ DSCP transparency в—Џ HSRP, VRRP, BLGP в—Џ RIPv1, v2 EIGRP, PIM OSPF, OSPFv3, EIGRPv6, BGPv4, IS-ISv4 в—Џ VRF-lite в—Џ PIM-SM/DM, PIM sparse-dense mode, SSM в—Џ Flexible Netflow Advanced Network security в—Џ Port security в—Џ DHCP snooping в—ЏDynamic ARP inspection (DAI) в—Џ IP source guard в—ЏThe Unicast Reverse Path Forwarding (uRPF) в—Џ Bidirectional data support on a SPAN в—Џ User authentication в—Џ Private VLAN в—ЏRouter and VLAN ACLs в—Џ complete identity and security в—Џ Multidomain authentication в—Џ MAC address notification в—Џ IGMP filtering в—Џ Cisco security VLAN ACL в—Џ Secure Shell (SSH) Protocol, Kerberos, and Simple Network Management Protocol Version 3 (SNMPv3) в—Џ Port-based ACLs в—Џ TrustSec SXP в—Џ IEEE 802.1ae в—Џ TACACS+ and RADIUS authentication в—Џ Cisco standard and extended IP security router ACLs в—Џ Bridge protocol data unit (BPDU) Guard в—Џ Spanning Tree Root Guard (STRG) в—Џ Wireless end-to-end security Management в—ЏBRIDGE-MIB в—ЏCISCO-AUTH-FRAMEWORK-MIB в—ЏCISCO-BGP4-MIB, BGP4-MIB в—ЏCISCO-BRIDGE-EXT-MIB в—ЏCISCO-BULK-FILE-MIB в—ЏCISCO-CABLE-DIAG-MIB в—ЏCISCO-CALLHOME-MIB в—ЏCISCO-CEF-MIB в—ЏCISCO-CIRCUIT-INTERFACE-MIB в—ЏCISCO-ENTITY-VENDORTYPE-OID-MIB в—ЏCISCO-CONTEXT-MAPPING-MIB в—ЏCISCO-DEVICE-LOCATION-MIB в—ЏCISCO-DHCP-SNOOPING-MIB в—ЏCISCO-EIGRP-MIB в—ЏCISCO-EMBEDDED-EVENT-MGR-MIB в—ЏCISCO-ENTITY-FRU-CONTROL-MIB в—ЏCISCO-ENTITY-SENSOR-MIB в—ЏENTITY-MIB в—ЏCISCO-ERR-DISABLE-MIB в—ЏCISCO-CONFIG-COPY-MIB в—ЏCISCO-FLOW-MONITOR-MIB в—ЏCISCO-FTP-CLIENT-MIB в—ЏCISCO-HSRP-EXT-MIB в—ЏCISCO-HSRP-MIB в—ЏCISCO-IETF-ISIS-MIB в—ЏCISCO-IF-EXTENSION-MIB в—ЏCISCO-IGMP-FILTER-MIB в—ЏCISCO-CONFIG-MAN-MIB в—ЏCISCO-IP-CBR-METRICS-MIB в—ЏCISCO-IPMROUTE-MIB в—ЏCISCO-IP-STAT-MIB в—ЏCISCO-IP-URPF-MIB в—ЏCISCO-L2L3-INTERFACE-CONFIG-MIB в—ЏCISCO-LAG-MIB в—ЏCISCO-LICENSE-MGMT-MIB в—ЏCISCO-MAC-AUTH-BYPASS-MIB в—ЏCISCO-MAC-NOTIFICATION-MIB в—ЏCISCO-MDI-METRICS-MIB в—ЏCISCO-FLASH-MIB в—ЏCISCO-OSPF-MIB в—ЏCISCO-OSPF-TRAP-MIB в—ЏCISCO-PAE-MIB в—ЏCISCO-PAGP-MIB в—ЏCISCO-PIM-MIB в—ЏCISCO-PING-MIB в—ЏCISCO-PORT-QOS-MIB в—ЏCISCO-PORT-SECURITY-MIBв—ЏCISCO-PORT-STORM-CONTROL-MIB в—ЏCISCO-POWER-ETHERNET-EXT-MIB в—ЏCISCO-PRIVATE-VLAN-MIB в—ЏCISCO-PROCESS-MIB в—ЏCISCO-PRODUCTS-MIBв—ЏCISCO-RF-MIB в—ЏCISCO-RTP-METRICS-MIB в—ЏCISCO-RTTMON-MIB в—ЏCISCO-SMART-INSTALL-MIB в—ЏCISCO-SNMP-TARGET-EXT-MIB в—ЏCISCO-STACKMAKER-MIB в—ЏCISCO-MEMORY-POOL-MIB в—ЏCISCO-STP-EXTENSIONS-MIB в—ЏCISCO-SYSLOG-MIB в—ЏCISCO-TCP-MIB в—ЏCISCO-UDLDP-MIB в—ЏCISCO-VLAN-IFTABLE-RELATIONSHIP-MIB в—ЏCISCO-VLAN-MEMBERSHIP-MIB в—ЏCISCO-VTP-MIB в—ЏEtherLike-MIB в—ЏHC-RMON-MIB в—ЏIEEE8021-PAE-MIB в—ЏIEEE8023-LAG-MIB в—ЏIF-MIB в—ЏIGMP-MIB в—ЏIGMP-STD-MIB в—ЏIP-FORWARD-MIB в—ЏIP-MIB в—ЏIPMROUTE-STD-MIB в—ЏLLDP-EXT-MED-MIB в—ЏLLDP-MIB в—ЏNOTIFICATION-LOG-MIB в—ЏOLD-CISCO-MEMORY-MIB в—ЏCISCO-CDP-MIB в—ЏPOWER-ETHERNET-MIB в—ЏRMON2-MIB в—ЏRMON-MIB в—ЏSNMP-COMMUNITY-MIB в—ЏSNMP-FRAMEWORK-MIB в—ЏSNMP-MPD-MIB в—ЏSNMP-NOTIFICATION-MIB в—ЏSNMP-PROXY-MIB в—ЏSNMP-TARGET-MIB в—ЏSNMP-USM-MIB в—ЏSNMPv2-MIB в—ЏSNMP-VIEW-BASED-ACM-MIB в—ЏTCP-MIB в—ЏUDP-MIB в—ЏCISCO-IMAGE-MIB в—ЏCISCO-STACKWISE-MIB в—ЏAIRESPMACE-WIRELESS-MIB в—ЏCISCO-LWAPP-IDS-MIB в—ЏCISCO-LWAPP-AP-MIB в—ЏCISCO-LWAPP-CCX-RM-MIB в—ЏCISCO-LWAPP-CLIENT-ROAMING-MIB в—ЏCISCO-LWAPP-DOT11-CCX-CLIENT-DIAG-MIB в—ЏCISCO-LWAPP-DOT11-CCX-CLIENT-MIB в—ЏCISCO-LWAPP-DOT11-CLIENT-CCX-REPORTS-MIB в—ЏCISCO-LWAPP-DOT11-CLIENT-MIB в—ЏCISCO-LWAPP-DOT11-MIB в—ЏCISCO-LWAPP-DOWNLOAD-MIB в—ЏCISCO-LWAPP-LINKTEST-MIB в—ЏCISCO-LWAPP-MFP-MIB в—ЏCISCO-LWAPP-MOBILITY-EXT-MIB в—ЏCISCO-LWAPP-QOS-MIB в—ЏCISCO-LWAPP-REAP-MIB в—ЏCISCO-LWAPP-ROGUE-MIB в—ЏCISCO-LWAPP-RRM-MIB в—ЏCISCO-LWAPP-SI-MIB в—ЏCISCO-LWAPP-TSM-MIB в—ЏCISCO-LWAPP-WLAN-MIB в—ЏCISCO-LWAPP-WLAN-SECURITY-MIB Technical Support and Services в—Џ Cisco SMARTnet Service в—Џ Cisco Smart Foundation Service в—Џ Cisco SP Base Service в—Џ Cisco Focused Technical Support Services Environmental Ranges With AC power supply Operating environment and altitude Operating temperature up to 5000 ft (1500 m) 23F to 113F (-5C to +45C) Operating temperature up to 10,000 ft (3000 m) 23F to 104F (-5C to +40C) Short-term exception at sealevel with single fan failure 23F to 113F (-5C to +45C) Short-term exception up to 5000 feet (1500 m) 23F to 122F (-5C to 50C) Short-term exception up to 10,000 feet (3000 m) 23F to 113F (-5C to 45C) With DC power supply Operating environment and altitude (NEBS) Operating temperature up to 6000 ft (1800 m) 23F to 113F (-5C to +45C) Operating temperature up to 10,000 ft (3000 m) 23F to 104F (-5C to +40C) Operating temperature up to 13,000 ft (4000m) 23F to 95F (-5C to 35C) Short-term exception up to 6,000 feet (1800 m) 23F to 131F (-5C to +55C) Short-term exception up to 10,000 feet (3000 m) 23F to 122F (-5C to +50C) Short-term exception up to 13,000 feet (4000 m) 23F to 113F (-5C to +45C) Short-term exception at sealevel with single fan failure 23F to 113F (-5C to +45) Storage environment -40F to 160F (-40C to 70C) Operating altitude Up to 13,000 Feet (Up to 4000 Meters) Storage altitude Up to 15,000 Feet (Up to 4573 Meters) Operating relative humidity 10% to 95% noncondensing Storage relative humidity 10% to 95% noncondensing Business

Tags

magnifier