CE16804-DC Overview Huwei CloudEngine 16800: Industrys First Data Center Switch, Built for the AI Era 1. The CloudEngine 16800 supports up to 36 x 100GE, 36 x 40GE, or 144 x 10GE line cards, which provide line-rate forwarding.The CloudEngine 16808 provides up to 288 x 100GE, 288 x 40GE, or 1152 x 10GE line-rate ports.Support 400GE ports in the future 2. Intelligent engine: embedded AI chip, implementing intelligent optimization of network-wide traffic and pre-analysis of network-wide abnormal traffic 3. Numerous features: M-LAG, VXLAN, EVPN, NSH, Telemetry, and iLossless AI algorithm Technical specifications of the CE16804-DC Item Specification Dimensions with packaging (H x W x D) [mm (in.)] 730 mm x 770 mm x 1150 mm (28.74 in. x 30.31 in. x 45.28 in.) Dimensions without packaging (H x W x D) [mm (in.)] 438 mm x 483 mm x 985 mm (17.24 in. x 19.02 in. x 38.78 in.) (including mounting brackets) Weight without packaging [kg (lb)] 98.1 kg (216.31 lb) (including two MPUs and filler panels) Weight without packaging (full configuration) [kg (lb)] 163.6 kg (360.74 lb) Weight with packaging [kg (lb)] 142 kg (313.11 lb) Cabinet installation standards A812 Chassis height [U] 9.8 U Redundant MPUs 1:1 Redundant Switch fabrics N+M Power supply mode DC Number of power modules 6 Redundant power supply Dual-input power supply system: N+1 backup is recommended. Single-input power supply system: N+1 backup Dual-input power supply is recommended to ensure reliability. Rated input voltage [V] -48 V/-60 V Input voltage range [V] -40 V to -72 V Maximum input current [A] 58.5 A for the voltage of -40 V Maximum output power [W] In 5+1 backup mode: 2200 W x 5 = 11000 W In 6+0 backup mode: 2200 W x 6 = 13200 W Certification Compliance with safety standards Compliance with EMC standards Compliance with environment and environmental protection standards Redundant fans Fan modules work in hot standby mode. At the normal temperature range, the system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. Heat dissipation mode Heat dissipation using fans Airflow direction Front-to-back airflow Availability 0.9999971695 MTBF [year] 34.93 year MTTR [hour] 1 hour Long-term operating altitude [m (ft.)] le, 5000 m (16404 ft.) (When the altitude is between 1800 m and 5000 m (5906 ft. and 16404 ft.), the highest operating temperature reduces by 1C (1.8F) every time the altitude increases by 220 m (722 ft.).) Long-term operating relative humidity [RH] 5% RH to 85% RH, noncondensing Long-term operating temperature [C (F)] 0C to 40C (32F to 104F) Storage altitude [m (ft.)] le, 5000 m (16404 ft.) Storage relative humidity [RH] 5% RH to 95% RH, noncondensing Storage temperature [C (F)] -40C to +70C (-40F to +158F)