No ACF gallery field data found

HUAWEI EH1D200CMU00 Centralized Monitoring Unit For Huawei Board

Brand Name: Huawei
Model Number: EH1D200CMU00
Minimum Order Quantity: 1 pc
Price: 
Delivery Time: 3-5 days
Warranty Time: 
Place of Origin: China
Payment Terms: 

Description

HUAWEI EH1D200CMU00 Centralized Monitoring Unit for Huawei board Product Description: EH1D200CMU00-Centralized Monitoring Unit Version Mapping Table 1 Switch chassis and software versions matching the card Card Name S12704 Chassis S12708 and S12712 Chassis S12710 Chassis EH1D200CMU00 Supported in V200R008C00 and later versions Supported in V200R005C00 and later versions Supported in V200R010C00 and later versions Introduction: The EH1D200CMU00 can be installed in: Slots CMU1 and CMU2 in an S12704 chassis. Slots CMU1 and CMU2 in an S12708 chassis. Slots CMU1 and CMU2 in an S12710 chassis. Slots CMU1 and CMU2 in an S12712 chassis. Figure 1 Appearance of EH1D200CMU00 Functions and Features: The EH1D200CMU00 consists of the following modules: Device management module: sends interface control signals for device management. Backplane interface module: provides management channels for power modules, fan modules, and communication channels between the active and standby EH1D200CMU00 cards. The EH1D200CMU00 manages power modules and fan modules in a chassis. The EH1D200CMU00 is hot swappable. Two EH1D200CMU00 cards can be installed in a chassis to work in active/standby mode. Fan Module Management: The EH1D200CMU00 provides the following fan module management functions. Fan module presence detection Fan module registration management Fan speed monitoring Fan speed control Management and report of fan module alarms Query of fan module electronic labels The EH1D200CMU00 supports real-time fan module presence detection. Fan modules in the chassis register with the EH1D200CMU00. After they register, the EH1D200CMU00 obtains electronic labels of the fan modules and saves the electronic labels for users to query. Meanwhile, the EH1D200CMU00 monitors the speed and alarms of the fan modules in real time. When detecting an alarm about a fan module, the EH1D200CMU00 reports the alarm to the MPU. When the alarm is cleared, the EH1D200CMU00 reports alarm clearance to the MPU. When the EH1D200CMU00 receives a fan speed adjustment instruction from the MPU, it delivers the instruction to the fan modules. The fan modules then adjust their speed according to the instruction. If a chassis has no EH1D200CMU00installed, fans run at full speed. Power Module Management: The EH1D200CMU00 provides the following power module management functions. Power module presence detection Power module shutdown Power module registration management Voltage and current monitoring Management and report of power module alarms Query of power module electronic labels The EH1D200CMU00 supports real-time power module presence detection. Power modules in the chassis register with the EH1D200CMU00. After they register, the EH1D200CMU00 obtains electronic labels of the power modules and saves the electronic labels for users to query. Meanwhile, the EH1D200CMU00 queries the current and voltage of power modules in real time. When detecting an alarm about a power module, the EH1D200CMU00 reports the alarm to the MPU. When the alarm is cleared, the EH1D200CMU00 reports alarm clearance to the MPU. When the switch is working in deep energy saving mode, the EH1D200CMU00 automatically shuts down redundant power modules to save power. You can set the deep energy saving mode using the set power manage mode command. Indicators and Ports Figure 2 Indicators on the EH1D200CMU00 panel Table 2 Indicators on the EH1D200CMU00 panel Number Indicator Color Description 1 RUN/ALM: running status indicator Green Slow blinking: The card software is running properly. Fast blinking: The card software is unregistered. Red Steady on: The card has failed, and the fault requires manual intervention. Slow blinking: The switch is reporting an alarm. For example, a CMU, fan module, or power module on the switch fails. Fast blinking: The input power is insufficient or a 1600 W DC power module is installed. 2 ACT: active/standby status indicator Green Steady on: The card is the active CMU. Off: The card is the standby CMU. Figure 3 Ports on the EH1D200CMU00 panel 1 One RS485 port (reserved) 2 One MON port (reserved) Specifications: Table 3 Specifications of the EH1D200CMU00 Item Description Physical specifications Dimensions (W x D x H): 112.9 mm x 412.7 mm x 19.8 mm (4.4 in. x 16.2 in. x 0.8 in.) Weight: 0.22 kg (0.49 lb) Maximum power consumption: 1 W Environment parameters Operating temperature: 0C to 45C (32F to 113F) Operating relative humidity: 5% RH to 95% RH (noncondensing) Storage temperature: -40C to +70C (-40F to +158F) Storage relative humidity: 5% RH to 95% RH (noncondensing) Ordering Information: Card ordering information is subject to updates with product version upgrades. The ordering information provided in this manual is for reference only. To obtain latest ordering information, contact Huawei switch distributors or Huawei local office. Table 4 Ordering information Part Number Card Description Card Model 03030NWB Centralized Monitoring Unit EH1D200CMU00 If you are interested, please let us know the specific model. We will provide the best service and the best price! Pr

Tags

magnifier