No ACF gallery field data found

S5731 - H48T4XC Huawei S Series Switches 100 BASE - T Ports 2 X 40GE

Brand Name: Huawei
Model Number: S5731-H48T4XC
Minimum Order Quantity: 1 pc
Price: 
Delivery Time: 3-5 days
Warranty Time: 
Place of Origin: China
Payment Terms: 

Description

Huawei S5731 - H48T4XC 48 10 / 100 / 1000 BASE - T ports 4 10GE SFP + ports The CloudEngine S5731-H series switches are the next-generation intelligent gigabit fixed switches developed by Huawei. The CloudEngine S5731-H builds on Huaweis unified Versatile Routing Platform (VRP) and boasts various IDN features. S5731-H48T4XC Specification Fixed port 48 x 10/100/1000Base-T ports, 4 x 10GE SFP+ ports Dimensions (H x W x D) 43.6 mm x 442 mm x 420mm Chassis height 1 U Chassis weight (including packaging) 8.55 kg Extended slot One extended slot, support 2 x 40GE, 8 x 10GE Base-T, 2 x 25GE SFP28 or 8 x 10GE SFP+ cards Power supply type 600 W AC (pluggable) 150 W AC (pluggable) 1000 W DC (pluggable) Rated voltage range AC input (600 W AC ): 100 V AC to 240 V AC, 50/60 Hz AC input (150 W AC ): 100 V AC to 240 V AC, 50/60 Hz DC input (1000 W DC): -48 VDC to -60 V DC Maximum voltage range AC input (150 W AC ): 90 V AC to 264 V AC, 47 Hz to 63 Hz AC input (600 W AC ): 90 V AC to 290 V AC, 45 Hz to 65 Hz High-voltage DC input (600 W AC): 190 V DC to 290 V DC (meeting 240 V high-voltage DC certification) DC input (1000 W DC): -38.4 V DC to -72V DC Maximum power consumption 124 W Noise Under normal temperature (sound power): 57.5dB (A) Under high temperature (sound power): 70.9dB (A) Under normal temperature (sound pressure): 47.5dB (A) Operating temperature 0-1800 m altitude: -5C to 45C 1800-5000 m altitude: The operating temperature reduces by 1C every time the altitude increases by 220 m. Storage temperature -40C to +70C Relative humidity 5% to 95% (non-condensing) Surge protection specification (service port) Common mode: plusmn,6 kV Surge protection specification (power port) AC power port: plusmn,6 kV in differential mode, plusmn,6 kV in common mode DC power port: plusmn,2 kV in differential mode, plusmn,4 kV in common mode Heat dissipation Air cooling heat dissipation, intelligent speed adjustment, and pluggable fans Service Features MAC address table IEEE 802.1d standards compliance 288K MAC address entries MAC address learning and aging Static, dynamic, and blackhole MAC address entries Packet filtering based on source MAC addresses VLAN 4094 VLANs Guest VLAN and voice VLAN GVRP MUX VLAN VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports VLAN mapping Wireless service AP access control, AP domain management, and AP configuration template management Radio management, unified static configuration, and dynamic centralized management WLAN basic services, QoS, security, and user management CAPWAP, tag/terminal location, and spectrum analysis Ethernet loop protection RRPP ring topology and RRPP multi-instance Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switching SEP ERPS (G.8032) BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) BPDU protection, root protection, and loop protection MPLS MPLS L3VPN MPLS L2VPN (VPWS/VPLS) MPLS-TE MPLS QoS IP routing Static routes, RIP v1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP, routing policy Up to 512K FIBv4 entries Up to 64K FIBv6 entries Interoperability VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST Link-type Negotiation Protocol (LNP), similar to DTP VLAN Central Management Protocol (VCMP), similar to VTP IPv6 features Up to 64K ND entries PMTU IPv6 Ping, IPv6 Tracert, and IPv6 Telnet ACLs based on source IPv6 addresses, destination IPv6 addresses, Layer 4 ports, or protocol types Multicast Listener Discovery snooping (MLDv1/v2) IPv6 addresses configured for sub-interfaces, VRRP6, DHCPv6, and L3VPN Multicast IGMP v1/v2/v3 snooping and IGMP fast leave Multicast forwarding in a VLAN and multicast replication between VLANs Multicast load balancing among member ports of a trunk Controllable multicast Port-based multicast traffic statistics IGMP v1/v2/v3, PIM-SM, PIM-DM, and PIM-SSM MSDP MVPN QoS/ACL Rate limiting in the inbound and outbound directions of a port Packet redirection Port-based traffic policing and two-rate three-color CAR Eight queues per port DRR, SP and DRR+SP queue scheduling algorithms WRED Re-marking of the 802.1p and DSCP fields of packets Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID Queue-based rate limiting and shaping on ports Security Hierarchical user management and password protection DoS attack defense, ARP attack defense, and ICMP attack defense Binding of the IP address, MAC address, port number, and VLAN ID Port isolation, port security, and sticky MAC MAC Forced Forwarding (MFF) Blackhole MAC address entries Limit on the number of learned MAC addresses IEEE 802.1x authentication and limit on the number of users on a port AAA authentication, RADIUS authentication, and HWTACACS authentication NAC SSH V2.0 HTTPS CPU protection Blacklist and whitelist Attack source tracing and punishment for IPv6 packets such as ND, DHCPv6, and MLD packets Secure Boot IPSec MACSec-256 ECA Deception Reliability LACP E-trunk Ethernet OAM (IEEE 802.3ah and IEEE 802.1ag) ITU-Y.1731 DLDP LLDP BFD for BGP, BFD for IS-IS, BFD for OSPF, BFD for static route VXLAN* VXLAN L2 and L3 gateways Centralized and distributed gateway BGP-EVPN Configured through the NETCONF protocol Super Virtual Fabric (SVF) Working as an SVF Parent to vertically virtualize downlink switches and APs as one device for management. A two-layer client architecture is supported. IGMP snooping can be enabled on access switches (ASs) and the maximum number of access users on a port can be configured. ASs can be independently configured. Services that are not supported by templates can be configured on the parent. Third-party devices are allowed between SVF parent and clients. Working as an SVF client that is plug-and-play with zero configuration iPCA Directly coloring service packets to collect real-time statistics on the number of lost packets and packet loss ratio Collection of statistics on the number of lost packets and packet loss ratio at network and device levels TWAMP Two-way IP link performance measurement Measurement on two-way packet delay, one-way packet loss rate, and one-way packet jitter Management and maintenance iStack, with up to 9 member switches in a stack SNMP v1/v2c/v3 RMON Smart Application Control (SAC) Web-based NMS System logs and alarms of different levels GVRP MUX VLAN NetStream Intelligent OM *CloudEngine S5731-H series switches require the VXLAN license or N1 advanced software package to support the VXLAN feature. the comparison. Product Code S5731-H24P4XC S5731-H24T4XC S5731-H48P4XC S5731-H48T4XC Fixed port 24 x 10/100/1000Base-T (PoE+) ports, 4 x 10GE SFP+ ports 24 x 10/100/1000Base-T ports, 4 x 10GE SFP+ ports 48 x 10/100/1000Base-T (PoE+) ports, 4 x 10GE SFP+ ports 48 x 10/100/1000Base-T ports, 4 x 10GE SFP+ ports Dimensions (H x W x D) 43.6 mm x 442 mm x 420mm 43.6 mm x 442 mm x 420mm 43.6 mm x 442 mm x 420mm 43.6 mm x 442 mm x 420mm Chassis height 1 U 1 U 1 U 1 U Chassis weight (including packaging) 8.6 kg 8.4 kg 8.8 kg 8.55 kg Extended slot One extended slot, support 2 x 40GE, 8 x 10GE Base-T, 2 x 25GE SFP28 or 8 x 10GE SFP+ cards One extended slot, support 2 x 40GE, 8 x 10GE Base-T, 2 x 25GE SFP28 or 8 x 10GE SFP+ cards One extended slot, support 2 x 40GE, 8 x 10GE Base-T, 2 x 25GE SFP28 or 8 x 10GE SFP+ cards One extended slot, support 2 x 40GE, 8 x 10GE Base-T, 2 x 25GE SFP28 or 8 x 10GE SFP+ cards Power supply type 1000 W PoE AC (pluggable) 600 W AC (pluggable) 150 W AC (pluggable) 1000 W DC (pluggable) 1000 W PoE AC (pluggable) 600 W AC (pluggable) 150 W AC (pluggable) 1000 W DC (pluggable) Rated voltage range AC input (1000 W AC PoE): 100 V AC to 240 V AC, 50/60 Hz AC input (600 W AC ): 100 V AC to 240 V AC, 50/60 Hz AC input (150 W AC ): 100 V AC to 240 V AC, 50/60 Hz DC input (1000 W DC): -48 VDC to -60 V DC AC input (1000 W AC PoE): 100 V AC to 240 V AC, 50/60 Hz AC input (600 W AC ): 100 V AC to 240 V AC, 50/60 Hz AC input (150 W AC ): 100 V AC to 240 V AC, 50/60 Hz DC input (1000 W DC): -48 VDC to -60 V DC Maximum power consumption 121 W (without PD) 977 W (with PD, PD power consumption of 720 W) 114 W 132 W (without PD) 1750 W (with PD, PD power consumption of 1440 W) 124 W

Tags

magnifier